Referenzliste
Ausgewählte Projekte seit 2000
Kunde / Customer |
Anwendung / Application |
Land / Country |
Abmessung / Dimension [mm] |
Beschichtung / Coating & lining |
Werkstoff / Steel grade |
Gesamtlänge / Total length [m] |
Tonnage [t] |
Jahr / Year |
Projekt / Project |
---|---|---|---|---|---|---|---|---|---|
Gasunie | Gas / CO2 | The Netherlands | 1.067 x 15,9 (42 x .626) | PE / EP | L415ME | 21.845 | 9.035 | 2023 | Porthos |
1.067 x 15,9 (42 x .626) | PP / EP | L415ME | 125 | 50 | |||||
1.067 x 18,9 (42 x .744) | PE / EP | L415ME | 3.830 | 1.880 | |||||
1.067 x 18,9 (42 x .744) | PP / EP | L485ME | 3.580 | 1.755 | |||||
Trans Europa Naturgas Pipeline GmbH & Co. KG | Gas | Germany |
1.016 x 12,3 (40 x .484) | PE/EP | L485ME | 63.023 | 20.166 | 2023 | TENP III |
1.016 x 13,0 (40 x .512) | PE/EP | 15.155 | 5.144 | ||||||
1.016 x 13,8 (40 x .543) | PE/EP | 2.837 | 1.011 | ||||||
1.016 x 13,8 (40 x .543) | PE+GFK/EP | 641 | 250 | ||||||
1.016 x 18,6 (40 x .732) | PE+GFK/EP | 181 | 93 | ||||||
914 x 11,1 (36 x .437) | PE/EP | 24.001 | 6.252 | ||||||
914 x 11,8 (36 x .465) | PE/EP | 7.078 | 1.952 | ||||||
914 x 12,5 (36 x .492) | PE/EP | 71 | 21 | ||||||
914 x 12,5 (36 x .492) | PE+GFK/EP | 152 | 48 | ||||||
914 x 16,2 (36 x .638) | PE+GFK/EP | 136 | 55 | ||||||
Open Grid Europe | Gas | Germany | 1.016 x 20,3 (40 x .799) | EP / PE | L415ME | 1.300 | 650 | 2023 |
LNG Terminal Wilhelmshaven-Anbindungs-Leitung (WAL II) |
1.016 x 21,0 (40 x .827) | EP/PE+GFK | L485ME | 195 | 101 | |||||
Gasunie | Gas | Germany |
914 x 13,5 (36 x .531) | EP / PE | L485 ME | 3.150 | 944 | 2023 | ETL 179 - Anbindungsleitung zum LNG-Terminal Stade |
914 x 16,4 (36 x .645) | EP / PE / GFK | 270 | 98 | ||||||
914 x 17,5 (36 x .688) | EP / PE | 137 | 53 | ||||||
GRTgaz | Gas | France |
762 x 18,4 (30 x .724) | PE/EP | L450ME | 1.550 | 525 | 2023 | Durance micro tunnelier |
SMID | Gas | Denmark | 762 x 10,0 (30x .394) | PE / EP | L485ME | 7.735 | 1.450 | 2023 | Energinet West Funen |
762 x 12,5 (30 x .492) | 11.812 | 2.755 | |||||||
762 x 14,2 (30 x .559) | 7.483 | 1.980 | |||||||
762 x 14,2 (30 x .559) | PE / GFK / EP | 473 | 126 | ||||||
762 x 17,5 (30 x .689) | 70 | 23 | |||||||
762 x 12,5 (30 x .492) | 928 | 215 | |||||||
Gasunie | Gas | Germany | 813 x 11,8 (32 x .465) | PE / EP | L485ME | 46.280 | 10.856 | 2022 / 2023 | ETL 180 - LNG Anbindungsleitung Brunsbüttel |
813 x 14,6 (32 x .575) | PE / GFK / EP | 1.146 | 335 | ||||||
813 x 13,2 (32 x .520) | 7.658 | 2.000 | |||||||
813 x 16,0 (32 x .630) | PE / EP | 260 | 83 | ||||||
813 x 11,8 (32 x .465) | bare / EP | 3.262 | 765 | ||||||
rff/Gascade | Gas | Germany |
610 x 16,0 (24 x .630) | RS/PE | L415 ME | 701 | 171 | 2022 | rff/NEL Anschluss LNG Terminal Lubmin |
Gasunie | H2 | The Netherlands | 610 x 11,1 (24 x .437) | PE / EP | X60 | 25.967 | 4.320 | 2022 | HyTransPort |
610 x 13,3 (24 x .524) | 4.140 | 815 | |||||||
610 x 11,1 (24 x .437) | PP/EP | X60 | 2.334 | 390 | |||||
Open Grid Europe | Gas | Germany | 1.016 x 19,6 (40 x .772) | EP / PE | L415 ME | 25.560 | 12.741 | 2022 |
LNG Terminal Wilhelmshaven-Anbindungs-Leitung (WAL) |
1.016 x 20,3 (40 x .799) | EP/PE+GFK | L485ME | 1.566 | 806 | |||||
WarmtelinQ | District Heating | The Netherlands | 711-1.016 x 8 up to 20 (28-40) x .315 up to .787 | PE & PP | P355NH TC2/L485ME | 18.839 | 4.827 | 2022 | Fernwärmeleitung WarmtelinQ |
ALPE | Water | Austria | 1.321 x 12 (52 x .472) | PE / EP / 500µm | P355NH | 3.619 | 1.470 | 2022 | Wasserkraftwerk Sellrain / Austria |
1.321 x 15,5 (52 x .610) | |||||||||
SMID/Net4Gas | Gas | Czech Republic | 1.016 x 12,0 (40 x .472) | PE / EP | X 70 | 82.827 | 26.025 | 2021 - 2022 | Moravia |
1.016 x 12,0 (40 x .472) | PE / GFK / EP | 989 | 339 | ||||||
1.016 x 13,5 (40 x .531) | PE / EP | 972 | 340 | ||||||
RAG | Water | Germany | 1.016 x 16 (40 x .630) | PE / bare | L485ME | 3.055 | 1.210 | 2021 - 2022 | Grubenwasserleitung Haus Aden |
Terega | Gas | France | 660 x 11,0 26 x .433 | PE / EP | X 65 | 9.175 | 1.635 | 2021 | Mont Ogenne |
660 x 18,0 (26 x .709) | PP / EP | 930 | 265 | ||||||
Open Grid Europe | Gas+B5:C25 | Germany | 711 x 8,0 (28 x .315) | PE / bare | L245NE | 3.870 | 555 | 2021 | NETG - Benrath Leitung 12 |
ALPE | Water | Austria | 1.626 x 16,0 (64 x .630) | bare / EP | P235TR2 | 1.620 | 1.030 | 2020 - 2021 | Nutzwasserleitung Voest |
1.626 x 17,5 (64 x .689) | |||||||||
SMID/SNAM | Gas | Italy | 660 x 11,0 26 x .433 | PE / EP | X 60 | 85.685 | 15.930 | 2020 | |
Gascade | Gas | Germany |
813 x 14,0 (32 x .551) | PE/EP | X 70 | 3.138 | 867 | 2020 | Line Pipes für Mantelrohrsanierung |
Gasunie | Gas | The Netherlands |
914 x 12,1 (36 x .476) | PE/EP | X70 | 4.382 | 1.293 | 2019 - 2020 | Mengstation N2 Zuidbroek |
914 x 17,1 (36 x .673) | |||||||||
SMID | Gas | Denmark | 1.016 x 13,0 (40 x .512) | PE/EP | X70 | 58.583 | 20.810 | 2019 - 2020 | Energinet Baltic Pipe Lot II |
1.016 x 16,0 (40 x .630) | |||||||||
1.016 x 20,0 (40 x .787) | |||||||||
SMID | Gas | Denmark |
1.016 x 13,0 (40 x .512) | PE / GFK / EP | X70 | 2.977 | 1.210 | 2019 - 2020 | Energinet Baltic Pipe Lot II |
1.016 x 16,0 (40 x .630) | |||||||||
1.016 x 20,0 (40 x .787) | |||||||||
ZEELINK | Gas | Germany | 1.016 x 16,8 (40 x .661) | PE / EP | X70 | 209.816 | 89.985 | 2018 - 2020 | ZEELINK Lot I + II |
1.016 x 17,9 (40 x .705) | |||||||||
1.016 x 19,5 (40 x .768) | |||||||||
1.016 x 19,5 (40 x .705) | PE / GFK / EP | X70 | 7.680 | 3.845 | 2018 - 2020 | ZEELINK Lot I + II | |||
1.016 x 20,3 (40 x .799) | |||||||||
TEREGA | Gas | France |
660 x 10,5 (26 x .413) | PE / EP | X65 | 3.022 | 532 | 2019 | Trois Villes |
660 x 17,5 (26 x .689) | PP / EP | 616 | 180 | ||||||
SMI / SNAM | Water | Italy | 1422 x 21,8 (56 x .858) | PE / EP | X65 | 5.424 | 4.125 | 2019 | |
Aquapipe | Water | Luxembourg | 914 x 11,0 (36 x .433) | PE / bare | X52 | 2.185 | 637 | 2019 | Wasserleitung Nospelt |
GRTgaz | Gas | France |
914 x 17,3 (36 x 0,681) | PE / EP | X70 | 1.550 | 596 | 2019 | Mitry Mory |
SMI / SNAM | Gas | Italy | 1.067 x 14,1 (42 x .555) | PE / EP | X65 | 14.620 | 5.365 | 2018 - 2019 | |
1.072 x 16,6 (42 x .653) | 2.973 | 1.288 | |||||||
927 x 19,6 (36 x .772) | 1.335 | 586 | |||||||
916 x 14,2 (36 x .559) | 1.830 | 580 | |||||||
1.072 x 16,6 (42 x .653) | 1.145 | 495 | |||||||
Izostal | Gas | Poland | 1.219 x 25,0 (48 x .984) | PP / RS | X65 | 1.140 | 840 | 2018 | Schutzrohre |
Indufer | Water | Switzerland | 813 x 10,2 (32 x .402) | PE / EP / 500µm | X70 | 133 | 60 | 2017 | Druckleitung Wasserkraftwerk Vouvry |
813 x 13,3 (32 x .524) | 7.040 | 3.290 |
2016 - 2017 | ||||||
813 x 16,4 (32 x .646) | 1.025 | 577 | |||||||
Indufer | Gas | Switzerland | 1.524 x 19,4 (60 x .764) | PE | X70 | 805 | 580 | 2018 | Gasspeicher Bulwil |
Open Grid Europe | Gas | Germany | 1.118 x 18,5 (44 x .728) | PE / EP | X70 | 14.170 | 7.295 | 2018 | LEL Erdgasleitung EPE - Legden |
1.118 x 22,4 (44 x .882) | PE / GFK / EP | 425 | 265 | ||||||
1.118 x 19,8 (44 x .779) | PE / EP | 185 | 100 | ||||||
Syndicat des eaux du barrage d'Esch-sur-Sûre (SEBES) | Water | Luxembourg |
1016 x 10,0 (40 x .393) | bare | X 52 | 12.758 | 3.151 | 2017 | SEBES Eschdorf (Luxembourg) |
Open Grid Europe | Gas | Germany |
1.219 x 20,7 (48 x .815) | PE / EP | X70 | 1.700 | 1.048 | 2017 | MüWeLa Ortsumgehung Werne-Schlüchtern |
1.219 x 22,5 (48 x .886) | PE / GFK / EP | 238 | 160 | ||||||
1.219 x 24,4 (48 x .960) | PE / GFK / EP | 55 | 40 | ||||||
Gascade | Gas | Germany |
1.016 x 16,0 (40 x .630) | PE / EP | X70 | 27.006 | 11.205 | 2017 | NOWAL |
Gascade | Gas | Germany |
1.016 x 17,4 (40 x .685) | PE / EP | X70 | 133 | 60 | 2017 | NOWAL |
Gasunie | Gas | The Netherlands |
1.219 x 15,6 (48 x .614) | bare | X70 | 7.040 | 3.290 |
2016 - 2017 | Bemmel Zevenaar |
Gasunie | Gas | The Netherlands |
1.219 x 18,9 (48 x .744) | bare | X70 | 1.025 | 577 |
2016 - 2017 | Bemmel Zevenaar |
Open Grid Europe | Gas | Germany |
1.016 x 16,8 (40 x .661) | PE / EP | X70 | 38.330 | 16.550 |
2016 - 2017 | LSF Erdgastransportleitung Schwandorf -Forchheim |
1.016 x 17,9 (40 x .705) | PE / EP | 24.280 | 11.100 | ||||||
1.016 x 17,9 (40 x .705) | PE / GFK / EP | 861 | 395 | ||||||
813 x 14,8 (32 x .583) | PE / EP | 313 | 95 | ||||||
610 x 11,2 (24 x .441) | PE / EP | 130 | 23 | ||||||
GRTgaz | Gas | France |
1.219 x 13,0 (48 x .512) | PE / EP | X70 | 22.880 | 9.120 | 2016 | Val de Saône |
1.219 x 15,4 (48 x .606) | 66.600 | 31.170 | |||||||
1.219 x 22,7 (48 x .893) | 3.110 | 2.110 | |||||||
1.219 x 22,7 (48 x .893) | PP / EP | 1.180 | 800 | ||||||
Mannesmann Line Pipe / SNAM | Gas | Italy |
660 x 15,9 (26 x 0,626) | PE / EP | X60 | 5.095 | 1.275 | 2016 | |
Izostal | Gas | Poland |
1.016 x 23,2 (40 x 0,913) | bare | X70 | 12.580 | 7.135 | 2016 |
Gaz System Czeszów-Kielszów |
Izostal | Gas | Poland |
1.016 x 22,9 (40 x 0,902) | bare | X70 | 8.100 | 4.560 | 2016 |
Gaz System Lwówek - Odolandów |
Izostal | Gas | Poland |
1.016 x 16,7 (40 x 0,657) | bare | X70 | 2.500 | 1.020 | 2016 |
Gaz System Lwówek - Odolandów |
Izostal | Gas | Poland |
711 x 18,2 (28 x 0,716) | bare | X70 | 6.070 | 1.885 | 2016 | Gaz System Strachocina |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
711 x 10,0 (28 x 0,393) | bare | P265GH | 1.432 | 247 | 2015 | Rheindüker/ Köln |
914 x 10,0 (36 x 0,393) | PP | 656 | 146 | ||||||
1.016 x 10,0 (40 x 0,393) | PP | 656 | 163 | ||||||
TKS Leipzig | Gas | Germany |
813 x 12,5 (32 x 0,492) | PE / EP | X70 | 13.984 | 3.605 | 2015 |
ONTRAS LMBV - FGL Lausitz |
813 x 8,8 (32 x 0,346) | L245NE | 26.286 | 4.949 | ||||||
Mannesmann Line Pipe / Stahlrohr | Gas | Germany |
1.420 x 14,2 (56 x 0,559) | bare |
S355J2H / P355N | 2.392 | 1.178 | 2015 | Stahlrohr |
Fluxys | Gas | Belgium |
914 x 17,8 (36 x 0,700) | PP / EP | X70 | 3.663 | 1.430 | 2015 | Alveringen - Maldegem |
914 x 13,4 (36 x 0,527) | PE / EP | X70 | 18.280 | 5.420 | |||||
GRTgaz | Gas | France |
914 x 9,8 (36 x 0,386) | PE / EP | X70 | 19.044 | 4.246 | 2015 | Artère du Santerre |
914 x 11,7 (36 x 0,461) | PE / EP | 13.823 | 3.638 | ||||||
914 x 17,3 (36 x 0,681) |
PP / EP PE / EP | 822 | 314 | ||||||
Project Materials / SASOL | Gas | Mozambique |
660 x 10,8 (26 x 0,425) | PE | X70 | 128.840 | 24.638 | 2015 | ROMPCO Loop Line 2 |
TKS Leipzig | Gas | Germany |
813 x 13,2 (32 x 0,528) | PE / EP | X75 | 36.660 | 9.550 |
2014 - 2015 | Katharina |
TKS Leipzig | Gas | Germany |
813 x 14,2 (32 x 0,559) | PE / GFK / EP | X75 | 740 | 210 |
2014 - 2015 | Katharina |
Piping Service Steuer | Gas | Germany |
762 x 14,2 (30 x 0,559) | PP / EP | X70 | 3.130 | 830 | 2014 | Elbedüker |
Piping Service Steuer | Gas | Germany |
762 x 14,2 (30 x 0,559) | PE / EP | X70 | 100 | 26 | 2014 | Elbedüker |
Mannesmann Line Pipe / National Grid | Gas | UK |
762 x 19,1 (30 x 0,752) | bare | X60 | 1.850 | 645 | 2014 | Willington Project |
Mannesmann Line Pipe / Perenco | Gas | Gabon |
762 x 19,1 (30 x 0,752) | bare | X52 | 2.555 | 890 | 2014 | Massongo / Fernan VAZ Project |
Cameroon |
762 x 19,1 (30 x 0,752) | 2.450 | 855 | ||||||
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
914 x 12,5 (36 x 0,492) | PP/ PE | P355NH | 1.912 | 510 |
2013 - 2014 | Fernwärmeleitung Düker Rotterdam |
914 x 14,2 (36 x 0,559) | PP / PE | 2.053 | 656 | ||||||
711 x 8,0 (28 x 0,315) | bare | 3.979 | 600 | ||||||
Indufer |
Erdgasspeicher / Gas storage | Switzerland |
1.524 x 19,4 (60 x 0,764) | PE / bare | X70 | 1.865 | 1.345 | 2013 | Erdgasspeicher Hohfirst |
GRTgaz | Gas | France |
914 x 16,4 (36 x 0,646) | PE / EP | X70 | 8.150 | 3.000 | 2013 | Haute de France II |
914 x 24,1 (36 x 0,949) | 1.450 | 760 | |||||||
914 x 24,1 (36 x 0,949) | 7.450 | 3.950 | |||||||
Izostal | Gas | Poland |
711 x 18,2 (28 x 0,717) | PE / EP | X70 | 9.700 | 3.020 | 2013 | Gazsystem |
TKS Leipzig | Gas | Germany |
813 x 14,2 (32 x 0,559) | PE / EP | X70 | 4.369 | 1.267 | 2013 | ONTRAS |
813 x 14,2 (32 x 0,559) | bare | 145 | 42 | ||||||
GRTgaz | Gas | France |
1.220 x 15,4 (48 x 0,606) | PE / EP | X70 | 125.360 | 57.200 | 2013 | Arc de Dierrey |
GRTgaz | Gas | France |
1.219 x 16,2 (48 x 0,638) | PE / EP | X70 | 26.730 | 13.158 |
2012 - 2013 | Hauts de France II/ Nédon-Cuvilly |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
914 x 10,0 (36 x 0,393) | bare | P355N | 1.888 | 421 | 2012 | Fernwärmeleitung Karlsruhe |
711 x 7,1 (28 x 0,279) | P355NH | 1.649 | 203 | Fernwärmeleitung Düker Rotterdam | |||||
711 x 12,5 (28 x 0,492) | 119 | 26 | |||||||
711 x 8,8 (28 x 0,346) | 170 | 26 | |||||||
711 x 10,0 (28 x 0,393) | PP | 2.089 | 361 | ||||||
711 x 10,0 (28 x 0,393) | 160 | 28 | |||||||
Open Grid Europe | Gas | Germany |
813 x 12,7 (32 x 0,500) | PE / EP | X70 | 1.075 | 535 | 2012 | Bierwang-Bichl |
Gasunie | Gas | The Netherlands |
610 x 11,1 (24 x 0,437) | bare | X60 | 5.307 | 876 | 2012 | Gasstorage Bergermeer |
610 x 13,3 (24 x 0,524) | 448 | 87 | |||||||
914 x 14,1 (36 x 0,555) | X70 | 996 | 315 | ||||||
914 x 17,1 (36 x 0,673) | 767 | 292 | |||||||
Stalprofil | Gas | Poland |
711 x 17,5 (28 x 0,689) | PE / EP | X70 | 13.000 | 4.000 | 2012 | Gazsystem |
Stalprofil | Gas | Poland |
711 x 17,5 (28 x 0,689) | PE / EP | X70 | 3.000 | 1.000 | 2012 | Gazsystem |
TKS Bremen für EWE | Gas | Germany |
914 x 16,0 (36 x 0,630) | PE / bare | X70 | 450 | 161 | 2012 | EWE - Anbindung Bunde-Oude |
914 x 21,0 (36 x 0,827) | RS / bare | 93 | 42 | ||||||
914 x 20,0 (36 x 0,787) | PE / bare | 207 | 93 | ||||||
914 x 20,0 (36 x 0,787) | PP / bare | 615 | 277 | ||||||
GRTgaz | Gas | France |
610 x 12,4 (24 x 0,488) | PE / EP | X70 | 1.017 | 202 | 2012 | Etrez ligne |
SMI / SNAM | Gas | Italy |
1.378,4 x 18,7 (56 x 0,736) | EP / PE | X65 | 14.418 | 9.400 | 2012 | |
Fluxys | Gas | Belgium |
610 x 9,0 (24 x 0,354) | EP / PE | X70 | 23.138 | 3.281 | 2012 | Ham - Herenthout |
Fluxys | Gas | Belgium |
617 x 12,5 (24 x 0,492) | bare | X60 | 1.047 | 195 | 2012 | Ham - Herenthout |
Fluxys | Gas | Belgium |
610 x 13,4 (24 x 0,528) | EP / PP | X70 | 3.029 | 625 | 2012 | Ham - Herenthout |
Izostal | Gas | Poland |
711 x 18,2 (28 x 0,717) | PE / EP | X70 | 5.640 | 1.750 | 2012 | Gazsystem |
Izostal | Gas | Poland |
711 x 18,2 (28 x 0,717) | PP / EP | X70 | 8.671 | 2.700 | 2012 | Gazsystem |
Gascade | Gas | France |
1.016 x 14,8 (40 x 0,583) | PE / EP | X70 | 89.700 | 32.800 | 2012 | Midal Süd Loop |
Gascade | Gas | France |
1.016 x 22,4 (40 x 0,882) | PP / EP | X70 | 135 | 75 | 2012 | Midal Süd Loop |
Izostal | Gas | Poland |
813 x 18,2 (32 x 0,716) | PE / EP | X80 | 300 | 110 | 2012 | Gazsystem |
Izostal | Gas | Poland |
813 x 11,7 (32 x 0,460) | PE / EP | X80 | 9.060 | 2.100 | 2012 | Gazsystem |
SMID / SICIM | Öl / Oil | Cameroon |
762 x 8,2 (30 x 0,323) | PE | X70 | 10.080 | 1.540 | 2012 | Loop Line |
SMID / SICIM | Öl / Oil | Cameroon |
762 x 10,0 (30 x 0,393) | PE | X70 | 10.070 | 1.870 | 2012 | Loop Line |
SMID / SICIM | Öl / Oil | Cameroon |
762 x 13,8 (30 x 0,543) | PE | X70 | 7.550 | 1.920 | 2012 | Loop Line |
Open Grid Europe | Gas | Germany |
1.016 x 17,5 (40 x 0,689) | PE / EP | X70 | 67.830 | 29.300 |
2011 - 2012 |
OGE Loop Sannerz - Rimpar |
Open Grid Europe | Gas | Germany |
1.016 x 20,7 (40 x 0,815) | PE / GFK / EP | X70 | 142 | 72 |
2011 - 2012 |
OGE Loop Sannerz - Rimpar |
Open Grid Europe | Gas | Germany |
1.016 x 17,5 (40 x 0,689) | PE / EP | X70 | 72.310 | 31.200 |
2011 - 2012 |
MEGAL Loop Schwandorf - Windberg |
Open Grid Europe | Gas | Germany |
1.016 x 20,7 (40 x 0,815) | PE / EP | X70 | 185 | 100 |
2011 - 2012 |
MEGAL Loop Schwandorf - Windberg |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
1.016 x 12,5 (40 x 0,492) | PE | P235TR1 | 1.670 | 515 | 2011 | Fernwärmeleitung Zagreb |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
1.120 x 12,5 (44 x 0,492) | PE | P235TR2 | 95 | 32 | 2011 | Fernwärmeleitung Zagreb |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
711 x 10,0 (28 x 0,393) | PE | P355N | 13.234 | 2.273 | 2011 | Diemen - Almere |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
711 x 10,0 (28 x 0,393) | PP | P355N | 3.210 | 550 | 2011 | Diemen - Almere |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
711 x 14,0 (28 x 0,551) | PE | P355N | 335 | 80 | 2011 | Diemen - Almere |
GSO | Gas | France |
610 x 15,3 (24 x 0,602) | PP / EP | X65 | 731 | 180 | 2011 | Euskadour |
RWE | Gas | Germany |
610 x 16 (24 x 0,630) | PE | X52 | 3.600 | 850 | 2011 |
Optimierungsleitung KW Gersteinwerk |
RWE | Gas | Germany |
610 x 16 (24 x 0,630) | PE / GFK / bare | X52 | 430 | 100 | 2011 |
Optimierungsleitung KW Gersteinwerk |
TIGF | Gas | France |
813 x 12,7 (32 x 0,500) | PE / EP | X70 | 55.620 | 13.880 | 2011 | Artère du Béarn |
SMID | Gas | Canada |
914 x 15,9 (36 x 0,625) | bare | Grade 241 Cat.1 | 2.105 | 740 | 2011 | MEG Energy |
SMID | Gas | Canada |
762 x 15,9 (30 x 0,625) | bare | Grade 241 Cat.2 | 648 | 189 | 2011 | MEG Energy |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
914 x 10,0 (36 x 0,393) | PE | P235TR1 | 515 | 115 | 2010 | Fernwärme Rostock |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 18,9 (48 x 0,744) | PE / EP | X65 | 21.000 | 11.780 | 2010 | |
Fluxys | Gas | Belgium |
610 x 9,0 (24 x 0,354) | PE / EP | X70 | 20.550 | 2.800 | 2010 | Carsid - Dampremy |
Fluxys | Gas | Belgium |
610 x 13,4 (24 x 0,528) | PP / EP | X70 | 1.800 | 360 | 2010 | Carsid - Dampremy |
Fluxys | Gas | Belgium |
1.016 x 14,9 (40 x 0,587) | PE / EP | X70 | 125.400 | 45.960 | 2010 | VTN II |
GRTgaz | Gas | France |
610 x 12,6 (24 x 0,496) | PE / EP | X65 | 23.500 | 4.630 | 2010 | Fos Martiques |
Gasunie | Gas | The Netherlands |
762 x 13,8 (30 x 0,543) | PE / EP | X60 | 735 | 190 | 2010 |
Gas roundabout Open Season 2012 |
Gasunie | Gas | The Netherlands |
914 x 14,1 (36 x 0,555) |
PE / EP PP / EP | X70 | 2.815 | 880 | 2010 |
Gas roundabout Open Season 2012 |
Gasunie | Gas | The Netherlands |
914 x 17,1 (36 x 0,673) |
PE / EP PP / EP | X70 | 1.440 | 545 | 2010 |
Gas roundabout Open Season 2012 |
Gasunie | Gas | The Netherlands |
1.067 x 19,1 (42 x 0,752) | PE / EP | X60 | 1.532 | 755 | 2010 |
Gas roundabout Open Season 2012 |
Gasunie | Gas | The Netherlands |
1.220 x 21,7 (48 x 0,854) | PE / EP | X60 | 2.170 | 820 | 2010 |
Gas roundabout Open Season 2012 |
Gasnetz Steiermark | Gas | Austria |
813 x 10,0 (32 x 0,394) | PE / EP | X70 | 29.325 | 5.865 | 2010 | Südschiene II |
Gasnetz Steiermark | Gas | Austria |
813 x 11,0 (32 x 0,433) | PE / EP | X70 | 5.750 | 1.275 | 2010 | Südschiene II |
Gasnetz Steiermark | Gas | Austria |
813 x 12,5 (32 x 0,492) | PE / EP | X70 | 3.275 | 825 | 2010 | Südschiene II |
Pembina | Gas | Canada |
1.372 x 13,7 (54 x 0,539) | bare | X65 | 1.322 | 665 | 2010 | Gas storage system |
Pembina | Gas | Canada |
1.372 x 25,4 (54 x 1) | bare | X65 | 213 | 180 | 2010 | Gas storage system |
RWE | Gas | Germany |
610 x 11,0 (24 x 0,433) | PE / EP | X70 | 13.130 | 2.155 | 2010 |
ONTRAS Speicherleitung Stassfurt |
RWE | Gas | Germany |
610 x 14,2 (24 x 0,559) | PE / EP | X70 | 1.380 | 310 | 2010 |
ONTRAS Speicherleitung Stassfurt |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 16,1 (48 x 0,634) | PE / EP | X65 | 45.000 | 21.450 | 2009 | |
Gasunie | Gas | The Netherlands |
1.219 x 18,7 (48 x 0,736) | PE / EP | X70 | 10.045 | 5.615 | 2009 | Gasrotonde fase 1 |
GRTgaz | Gas | France |
914 x 17,3 (36 x 0,681) | PE / EP | X70 | 10.076 | 3.850 | 2009 | Artère de Beauche |
Wingas | Gas | Germany |
1.220 x 20,7 (48 x 0,815) | PE / EP | X70 | 2.500 | 1,550 | 2009 | Umverlegung Jagal |
RAG | Gas | Austria |
914 x 14,4 (36 x 0,567) | PE / EP | X70 | 23.100 | 7.520 | 2009 | Leitung UGS NBZ / 7 Fields |
RAG | Gas | Austria |
914 x 16,2 (36 x 0,638) | PE / EP | X70 | 2.650 | 940 | 2009 | Leitung UGS NBZ / 7 Fields |
RAG | Gas | Austria |
914 x 17,8 (36 x 0,701) | PE / EP | X70 | 860 | 350 | 2009 | Leitung UGS NBZ / 7 Fields |
OMV | Gas | Austria |
1.220 x 18,7 (48 x 0,736) | PE / EP | X70 | 49.160 | 27.575 | 2009 | WAG LOOP BE |
OMV | Gas | Austria |
1.220 x 21,1 (48 x 0,831) | PE / EP | X70 | 360 | 228 | 2009 | WAG LOOP BE |
OMV | Gas | Austria |
813 x 12,6 (32 x 0,496) | PE / EP | X70 | 4.484 | 1.127 | 2009 | WAG LOOP BE |
Gasnetz Steiermark | Gas | Austria |
813 x 10,0 (32 x 0,394) | PE / EP | X70 | 50.610 | 10.225 | 2009 | Südschiene I |
Gasnetz Steiermark | Gas | Austria |
813 x 11,0 (32 x 0,433) | PE / EP | X70 | 8.300 | 1.845 | 2009 | Südschiene I |
Gasnetz Steiermark | Gas | Austria |
813 x 12,5 (32 x 0,492) | PE / EP | X70 | 5.800 | 1.460 | 2009 | Südschiene I |
Gasunie | Gas | Netherlands |
1.219 x 15,9 (48 x 0,626) | PE / EP | X70 | 32.134 | 15.305 | 2009 | Gasrotonde |
IWB Industrielle Werke Basel |
Erdgasspeicher / Gas storage | Switzerland |
1.524 x 19,4 (60 x 0,764) | PE / EP | X70 | 2.895 | 2.085 | 2008 | Erdgasspeicher Allschwil / Basel |
Regio Energie Solothurn |
Erdgasspeicher / Gas storage | Switzerland |
1.524 x 19,4 (60 x 0,764) | PE / EP | X70 | 3.845 | 2.775 | 2008 | Erdgasspeicher Etziken / Solothurn |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
1.016 x 8,8 (40 x 0,346) | bare | P235GH | 6.345 | 1.965 |
2007 - 2008 | Dänemark/ Kopenhagen |
Kinder Morgan | Gas | USA |
1.067 x 13,7 (42 x 0,539) | FBE / EP | X70 | 176.200 | 62.760 |
2007 - 2008 | Louisiana Pipeline |
Kinder Morgan | Gas | USA |
1.067 x 18,3 (42 x 0,720) | FBE / EP | X70 | 14.400 | 6.800 |
2007 - 2008 | Louisiana Pipeline |
Kinder Morgan | Gas | USA |
1.067 x 14,1 (42 x 0,555) | FBE / EP | X70 | 295.000 | 107.960 |
2006 - 2008 | Rockies Express Pipeline |
Kinder Morgan | Gas | USA |
1.067 x 18,8 (42 x 0,740) | FBE / EP | X70 | 124.500 | 60.500 |
2006 - 2008 | Rockies Express Pipeline |
e.on Ruhrgas | Gas | Germany |
813 x 14,2 (32 x 0,559) | PE / EP | X70 | 11.100 | 3.110 | 2007 | Lichtenbusch - Stolberg |
e.on Ruhrgas | Gas | Germany |
813 x 15,9 (32 x 0,626) | PP / EP | X70 | 450 | 140 | 2007 | Lichtenbusch - Stolberg |
e.on Ruhrgas | Gas | Germany |
813 x 14,2 (32 x 0,559) | PE / EP | X70 | 11.930 | 3.340 | 2007 | Forchheim - Irsching |
e.on Ruhrgas | Gas | Germany |
813 x 15,0 (32 x 0,591) | PP / EP | X70 | 500 | 150 | 2007 | Forchheim - Irsching |
e.on Ruhrgas | Gas | Germany |
813 x 15,9 (32 x 0,626) | PP / EP | X70 | 120 | 40 | 2007 | Forchheim - Irsching |
Fluxys | Gas | Belgium |
610 x 13,4 (24 x 0,528) | PP / EP | X70 | 633 | 125 | 2007 | Buizenpark Winksele |
Fluxys | Gas | Belgium |
1.016 x 19,8 (40 x 0,780) | PP / EP | X70 | 944 | 460 | 2007 | Buizenpark Winksele |
SMI / SNAM Rete Gas | Gas | Italy |
610 x 11,1 (24 x 0,437) | PE / EP | X60 | 22.240 | 3.685 | 2007 | |
SMI / SNAM Rete Gas | Gas | Italy |
762 x 14,3 (30 x 0,563) | PE / EP | X60 | 5.245 | 1.385 | 2007 | |
TIGF | Gas | France |
914 x 21,3 (36 x 0,839) | PE / EP | X70 | 7.018 | 3.272 | 2007 | Artère du Guyenne |
TIGF | Gas | France |
914 x 21,3 (36 x 0,839) | PP / EP | X70 | 1.388 | 647 | 2007 | Artère du Guyenne |
Stroytransgaz Russia | Gas | Algeria |
1.067 x 20,6 (42 x 0,811) | PE / EP | X70 | 14.100 | 7.500 | 2006 | Sougueur à Hadjeret |
Gaz de France / C4Gas | Gas | France |
762 x 15,0 (30 x 0,591) | PE / EP | X70 | 2.373 | 655 | 2006 | Mirabeau Diversion |
Gaz de France / C4Gas | Gas | France |
1.219 x 17,5 (48 x 0,689) | PE / EP | X70 | 9.640 | 4.985 | 2006 |
Fos Cavaou St. Martin Pipeline |
National Grid / C4Gas | Gas | UK |
610 x 9,5 (24 x 0,374) |
FBE / EP (Eupec) | X52 | 15.250 | 2.140 | 2006 | Ilchester to Barrington |
e.on Ruhrgas | Gas | Germany |
813 x 14,2 (32 x 0,559) | PE / EP | X70 | 81.840 | 22.900 | 2006 | Stolberg - Porz |
e.on Ruhrgas | Gas | Germany |
813 x 16,0 (32 x 0,630) | PE / EP | X70 | 3.160 | 1.000 | 2006 | Stolberg - Porz |
Stadtwerke Hameln | Gas | Germany |
610 x 10,6 (24 x 0,417) | PE | X70 | 3.730 | 590 | 2006 | Storage Pipeline |
OMV | Gas | Austria |
1.016 x 12,5 (40 x 0,492) | PE / EP | X70 | 32.650 | 10.100 | 2006 |
TAG LOOP II Section Lichtenegg - Grafendorf |
OMV | Gas | Austria |
1.016 x 14,6 (40 x 0,575) | PE / EP | X70 | 2.070 | 750 | 2006 |
TAG LOOP II Section Lichtenegg - Grafendorf |
OMV | Gas | Austria |
1.016 x 12,5 (40 x 0,492) | PE / EP | X70 | 31.845 | 9.850 | 2006 |
TAG LOOP II Section Ludmannsdorf - Border A |
OMV | Gas | Austria |
1.020 x 14,6 (40 x 0,575) | PE / EP | X70 | 3.030 | 1.097 | 2006 |
TAG LOOP II Section Ludmannsdorf - Border A |
OMV | Gas | Austria |
1.216,5 x 16,1 (48 x 0,634) | PE / EP | X65 | 3.852 | 1.835 | 2006 |
TAG LOOP II Section Ludmannsdorf - Border A |
OMV | Gas | Austria |
1.222,1 x 18,9 (48 x 0,744) | PE / EP | X65 | 607 | 340 | 2006 |
TAG LOOP II Section Ludmannsdorf - Border A |
SMI / SNAM Rete Gas | Gas | Italy |
610 x 14,3 (24 x 0,563) | PE / EP | X60 | 3.300 | 693 | 2006 | |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 14.518 | 4.600 | 2006 | Iffezheim - Schwarzach |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 305 | 102 | 2006 | Iffezheim - Schwarzach |
TENP | Gas | Germany |
1.320 x 17,1 (52 x 0,673) | PE | X70 | 621 | 347 | 2006 | Iffezheim - Schwarzach |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 8.585 | 2.719 | 2006 | Reichenbach - Mittelbrunn |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 7.334 | 2.445 | 2006 | Reichenbach - Mittelbrunn |
TENP | Gas | Germany |
1.016 x 13,9 (40 x 0,547) | PE / EP | X70 | 937 | 330 | 2006 | Reichenbach - Mittelbrunn |
TENP | Gas | Germany |
1.320 x 17,1 (52 x 0,673) | PE | X70 | 310 | 173 | 2006 | Reichenbach - Mittelbrunn |
Fluxys | Gas | Belgium |
610 x 9,0 (24 x 0,354) | PE / EP | X70 | 10.115 | 1.336 | 2006 | Herentals - Zandhoven |
OMV | Gas | Austria |
914 x 14,0 (36 x 0,51) | PE / EP | X65 | 1.400 | 435 | 2006 | TAG EXP 04 |
SMI / SNAM Rete Gas | Gas | Italy |
762 x 14,3 (30 x 0,563) | PE / EP | X60 | 32.100 | 8.465 | 2006 | |
Sofresid / Sagess | Öl / Oil | France |
610 x 10,0 (24 x 0,394) | PE | X60 | 14.750 | 2.185 | 2006 | Fos-sur-Mer - Manosque |
Sofresid / Sagess | Öl / Oil | France |
610 x 11,0 (24 x 0,433) | PE | X60 | 6.800 | 1.105 | 2006 | Fos-sur-Mer - Manosque |
Sofresid / Sagess | Öl / Oil | France |
610 x 12,5 (24 x 0,492) | PE | X60 | 26.680 | 4.920 | 2006 | Fos-sur-Mer - Manosque |
Sofresid / Sagess | Öl / Oil | France |
610 x 14,2 (24 x 0,559) | PE | X60 | 12.575 | 2.625 | 2006 | Fos-sur-Mer - Manosque |
Sofresid / Sagess | Öl / Oil | France |
610 x 16,0 (24 x 0,630) | PE | X60 | 9.785 | 2.225 | 2006 | Fos-sur-Mer - Manosque |
Sofresid / Sagess | Öl / Oil | France |
610 x 16,0 (24 x 0,630) | PP | X60 | 1.550 | 365 | 2006 | Fos-sur-Mer - Manosque |
Nedeximpo |
Rammrohre / Piling pipes | Kazakhstan |
1.168 x 20,0 (46'' x 0,787'') | bare | S420MLH | 4.030 | 2.283 | 2005 | |
Saggas | Gas | Spain |
762 x 17,5 (30 x 0,689) | PE / EP | X70 | 7.650 | 2.470 | 2005 | Gasoducto de Transporte de Sagunto |
TIGF | Gas | France |
813 x 12,0 (32 x 0,472) | PE / EP | X70 | 27.500 | 6.520 | 2005 | Barran - Lussan |
TIGF | Gas | France |
813 x 17,7 (32 x 0,697) | PE / EP | X70 | 1.000 | 350 | 2005 | Barran - Lussan |
TIGF | Gas | France |
813 x 21,05 (32 x 0,829) | bare | X65 | 130 | 60 | 2005 | Barran - Lussan |
SMI / SNAM Rete Gas | Gas | Italy |
1.626 x 19,1 (64 x 0,752) | PE | X60 | 1.890 | 1.430 | 2005 | |
Fluxys / C4Gas | Gas | Belgium |
610 x 9,0 (24 x 0,354) | PE / EP | X70 | 20.035 | 2.597 | 2005 | Zomergen - Zelzate |
EWE Oldenburg | Gas | Germany |
610 x 10,7 (24 x 0,421) | PE | X70 | 6.590 | 1.022 | 2005 | |
EWE Oldenburg | Gas | Germany |
610 x 12,5 (24 x 0,492) | PE | X70 | 312 | 56 | 2005 | |
Stadtwerke Halberstadt | Gas | Germany |
610 x 10,0 (24 x 0,394) | PE | X70 | 2.327 | 344 | 2005 | Nordeinspeisung HSW |
VNG | Gas | Germany |
610 x 10,0 (24 x 0,394) | PE / EP | X70 | 27.079 | 4.006 | 2005 | FGL 227 Pritzwalk - Perleberg |
VNG | Gas | Germany |
610 x 11,6 (24 x 0,457) | PE / EP | X70 | 294 | 50 | 2005 | FGL 227 Pritzwalk - Perleberg |
Gasunie | Gas | The Netherlands |
914 x 14,5 (36 x 0,571) | bare | X70 | 23.310 | 7.490 | 2005 | Noorwesthoek - Maasvlathe |
Gasunie | Gas | The Netherlands |
914 x 17,5 (36 x 0,689) | bare | X70 | 7.500 | 2.890 | 2005 | Noorwesthoek - Maasvlathe |
Fluxys / C4Gas | Gas | Belgium |
610 x 9,0 (24 x 0,354) | PE / EP | X70 | 40.560 | 5.423 | 2005 | Weelde - Zandhoven |
Fluxys / C4Gas | Gas | Belgium |
610 x 13,4 (24 x 0,528) | PP / EP | X70 | 1.017 | 202 | 2005 | Weelde - Zandhoven |
OMV | Gas | Austria |
1.016 x 12,5 (40 x 0,492) | PE / EP | X70 | 39.000 | 12.090 | 2005 |
TAG LOOP II Section Hollenegg - Ruden |
OMV | Gas | Austria |
1.016 x 14,6 (40 x 0,575) | PE / EP | X70 | 4.050 | 1.470 | 2005 |
TAG LOOP II Section Hollenegg - Ruden |
OMV | Gas | Austria |
965 x 14,6 (38 x 0,575) | PE / EP | X70 | 1.165 | 400 | 2005 |
TAG LOOP II Section Hollenegg - Ruden |
OMV | Gas | Austria |
1.067 x 15,2 (42 x 0,598) | PE / EP | X70 | 1.520 | 600 | 2005 |
TAG LOOP II Section Hollenegg - Ruden |
RAG | Gas | Austria |
914 x 14,2 (36 x 0,559) | PE / EP | X70 | 38.013 | 11.962 | 2005 | ABG Leitung |
RAG | Gas | Austria |
914 x 16,0 (36 x 0,630) | PE / EP | X70 | 2.545 | 904 | 2005 | ABG Leitung |
Megagaz | Gas | Poland |
813 x 14,2 (32 x 0,559) | bare | X65 | 25.360 | 7.115 |
2003 - 2005 | |
Indufer |
Erdgasspeicher / Gas storage | Switzerland |
813 x 12,7 (32 x 0,500) | PE / bare | X 70 | 2.260 | 570 | 2004 | Erdgasspeicher Lugano |
Ruhrgas | Gas | Germany |
914 x 11,2 (36 x 0,441) | PE / EP | X70 | 1.830 | 460 | 2004 | Umlegung Schliengen |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
660 x 10,0 (26 x 0,393) | PE | St 52.0 | 1.380 | 221 | 2004 | Solothurn Schweiz |
Salzgitter Mannesmann Stahlhandel |
Fernwärme / District heating | Germany |
914 x 10,0 (36 x 0,393) | PE | P235TR1 | 840 | 187 | 2004 | Solothurn Schweiz |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 16,1 (48 x 0,634) | PE / EP | X65 | 28.000 | 13.345 | 2004 | |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 18,9 (48 x 0,744) | PE / EP | X65 | 22.000 | 12.338 | 2004 | |
Fluxys | Gas | Belgium |
610 x 13,4 (24 x 0,528) | PP / EP | X70 | 1.000 | 200 | 2004 | |
Rosenheim | Gas | Germany |
1.564 x 19,0 (61,5 x 0,748) | PE | X70 | 540 | 400 | 2004 | |
Gasunie | Gas | The Netherlands |
610 x 11,1 (24 x 0,437) | bare | X60 | 14.600 | 2.410 | 2004 | Enschede - Bornerbroek |
Gasunie | Gas | The Netherlands |
610 x 13,3 (24 x 0,524) | bare | X60 | 16.100 | 3.150 | 2004 | Enschede - Bornerbroek |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 16,1 (48 x 0,634) | PE / EP | X65 | 6.200 | 2.970 | 2004 | |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 18,9 (48 x 0,744) | PE / EP | X65 | 24.100 | 13.500 | 2004 | |
GSO | Gas | France |
610 x 10,0 (24 x 0,394) | PE / EP | X65 | 24.920 | 3.970 | 2004 | Euskadour |
GSO | Gas | France |
610 x 17,5 (24 x 0,689) | bare | X65 | 190 | 50 | 2004 | Euskadour |
GSO | Gas | France |
610 x 15,3 (24 x 0,602) | PE / EP | X65 | 726 | 170 | 2004 | Euskadour |
Gasunie | Gas | The Netherlands |
1.220 x 18,7 (48 x 0,736) | bare | X70 | 4.500 | 2.500 | 2004 | Noordbroek - Tripscompagnie |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 15.650 | 4.803 | 2003 | Sienhachenbach - Reichbach |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 6.370 | 2.064 | 2003 | Sienhachenbach - Reichbach |
TENP | Gas | Germany |
1.016 x 13,9 (40 x 0,547) | PE / EP | X70 | 3.090 | 1.061 | 2003 | Sienhachenbach - Reichbach |
TENP | Gas | Germany |
1.320 x 17,1 (52 x 0,673) | PE | X52 | 250 | 137 | 2003 | Sienhachenbach - Reichbach |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 18.143 | 5.652 | 2003 | Tiengen - Hügelheim |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 12 | 4.030 | 2003 | Tiengen - Hügelheim |
TENP | Gas | Germany |
1.320 x 17,1 (52 x 0,673) | PE | X70 | 346 | 190 | 2003 | Tiengen - Hügelheim |
Enagas | Gas | Spain |
813 x 9,5 (32 x 0,374) | bare | X70 | 39.826 | 7.500 | 2003 | Getafe - Salida a Cuenca |
Enagas | Gas | Spain |
813 x 11,9 (32 x 0,469) | bare | X70 | 12.416 | 2.920 | 2003 | Getafe - Salida a Cuenca |
Wintershall | Gas | Germany |
813 x 13,2 (32 x 0,520) | PE / EP | X70 | 2.240 | 601 | 2003 | Eisenach |
VNG | Gas | Germany |
610 x 8,8 (24 x 0,346) | PE / EP | X52 | 15.840 | 2.066 | 2003 | Buchholz - Fichtenwalde |
VNG | Gas | Germany |
813 x 11,9 (32 x 0,469) | PE / EP | X70 | 1.444 | 333 | 2003 | FGL 214 |
Gasunie | Gas | Netherlands |
1,219 x 18,7 (48 x 0,736) | bare | X70 | 512 | 285 | 2003 | Ravenstein - Vinkel |
EWE Oldenburg | Gas | Germany |
610 x 10,7 (24 x 0,421) | PE | X70 | 14.255 | 2.250 | 2003 | |
EWE Oldenburg | Gas | Germany |
610 x 12,5 (24 x 0,492) | PE | X70 | 2.270 | 417 | 2003 | |
VNG | Gas | Germany |
813 x 12,5 (32 x 0,492) | PE / EP | X70 | 919 | 227 | 2003 |
Extension FGL 216 BAB A 72 Hartmannsdorf |
SMI / SNAM Rete Gas | Gas | Italy |
1.200 x 16,1 (48 x 0,634) | PE / EP | X65 | 26.000 | 12.370 | 2003 | |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 18,9 (48 x 0,744) | PE / EP | X65 | 29.000 | 16.260 | 2003 | |
Fluxys | Gas | Belgium |
610 x 8,6 (24 x 0,339) | PE / EP | X70 | 44.715 | 5.930 | 2003 | Dilsen - Lommel |
Fluxys | Gas | Belgium |
610 x 13,4 (24 x 0,528) |
PP / EP (Conline) | X70 | 4.100 | 830 | 2003 | Dilsen - Lommel |
Fluxys | Gas | Belgium |
610 x 8,6 (24 x 0,339) | PE / EP | X70 | 821 | 109 | 2003 | Dilsen - Lommel |
Fluxys | Gas | Belgium |
610 x 8,6 (24 x 0,339) | PE / EP | X70 | 664 | 88 | 2003 | Dilsen - Lommel |
Enagas | Gas | Spain |
813 x 9,5 (32 x 0,374) | bare | X70 | 157.700 | 29.860 |
2002 - 2003 | Getafe - Cordoba |
Enagas | Gas | Spain |
813 x 11,9 (32 x 0,469) | bare | X70 | 11.800 | 2.775 |
2002 - 2003 | Getafe - Cordoba |
Enagas | Gas | Spain |
813 x 14,3 (32 x 0,563) | bare | X70 | 5.320 | 1.500 |
2002 - 2003 | Getafe - Cordoba |
Enagas | Gas | Spain |
813 x 17,5 (32 x 0,689) | bare | X70 | 555 | 190 |
2002 - 2003 | Getafe - Cordoba |
Erdgas Ostschweiz |
Erdgasspeicher / Gas storage | Switzerland |
1.524 x 19,4 (60 x 0,764) | PE / bare | X70 | 5.500 | 4.018 | 2002 | Erdgasspeicher Gutenswil |
Gaz de France | Gas | France |
914 x 13,7 (36 x 0,539) | PE / EP | X70 | 10.470 | 3.185 | 2002 | Artère du Centre |
MOL | Gas | Hungary |
813 x 12,5 (32 x 0,492) | PE | X70 | 1.540 | 380 | 2002 | Pipeline Rehabilitation |
SMI / SNAM Rete Gas | Gas | Italy |
559 x 10,3 (22 x 0,406) | PE / EP | X60 | 1.050 | 153 | 2002 | |
Gaz de France | Gas | France |
813 x 10,8 (32 x 0,425) | PE / EP | X70 | 82.260 | 17.628 | 2002 | Artère du Guyenne |
Gaz de France | Gas | France |
813 x 13,0 (32 x 0,512) | PE / EP | X70 | 5.930 | 1.523 | 2002 | Artère du Guyenne |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 13.200 | 4.051 | 2002 | Wickenrodt - Sienhachen- bach |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 2.650 | 858 | 2002 | Wickenrodt - Sienhachen- bach |
TENP | Gas | Germany |
1.016 x 13,9 (40 x 0,547) | PE / EP | X70 | 620 | 213 | 2002 | Wickenrodt - Sienhachen- bach |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 15.610 | 4.791 | 2002 | Elchesheim - Iffezheim |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 17 | 6 | 2002 | Elchesheim - Iffezheim |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 17.484 | 5.366 | 2002 | Bahlingen - Tiengen |
TENP | Gas | Germany |
914 x 11,2 (36 x 0,441) | PE / EP | X70 | 13.155 | 3.281 | 2002 | Hüsingen - Wallbach |
TENP | Gas | Germany |
914 x 11,9 (36 x 0,469) | PE / EP | X70 | 1,309 | 347 | 2002 | Hüsingen - Wallbach |
TENP | Gas | Germany |
914 x 16,0 (36 x 0,630) | PE / EP | X70 | 440 | 156 | 2002 | Hüsingen - Wallbach |
MOL | Gas | Hungary |
610 x 12,5 (24 x 0,492) | PE | X60 | 3.940 | 725 | 2002 | |
MOL | Gas | Hungary |
711 x 14,2 (28 x 0,559) | PE | X60 | 652 | 160 | 2002 | |
Thyssengas | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 229 | 70 | 2002 | Emsbüren - Hünxe |
Sasol | Gas | South Africa |
660 x 11,6 (26 x 0,457) | PE | X65 | 101.260 | 19.180 | 2002 | Temane - Secunda |
EVI Energieversorgung Hildesheim |
Erdgasspeicher / Gas storage | Germany |
1.420 x 16,0 (56 x 0,630) | PE / bare | X75 | 4.020 | 1.160 |
2001 - 2002 | Erweiterung Erdgasspeicher DN 1400 |
ExxonMobil | Öl / Oil |
Chad - Cameroon |
762 x 9,83 (30 x 0,387) | PE | X70 | 364.083 | 66.390 |
2000 - 2002 | |
ExxonMobil | Öl / Oil |
Chad - Cameroon |
762 x 11,71 (30 x 0,461) | PE | X70 | 265.053 | 57.420 |
2000 - 2002 | |
Stadtwerke Bietigheim - Bissingen |
Erdgasspeicher / Gas storage | Germany |
1.422 x 17,0 (56 x 0,669) | PE / bare | X70 | 1.120 | 720 | 2001 | Erdgasspeicher Bietigheim - Bissingen |
Gaz de France | Gas | France |
914 x 11,3 (36 x 0,445) | PE / EP | X70 | 68.520 | 17.240 | 2001 | Artère du Centre |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 36.330 | 11.255 | 2001 | Schwanheim - Elchesheim |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 4.660 | 1.520 | 2001 | Schwanheim - Elchesheim |
TENP | Gas | Germany |
1.016 x 13,9 (40 x 0,547) | PE / EP | X70 | 2.135 | 740 | 2001 | Schwanheim - Elchesheim |
TENP | Gas | Germany |
1.016 x 12,4 (40 x 0,488) | PE / EP | X70 | 49.340 | 15.145 | 2001 | Eckartsweier - Bahlingen |
TENP | Gas | Germany |
1.016 x 13,1 (40 x 0,516) | PE / EP | X70 | 290 | 95 | 2001 | Eckartsweier - Bahlingen |
Gaz de France | Gas | France |
813 x 18,1 (32 x 0,713) | PE / EP | X70 | 1.600 | 570 | 2001 | Artère du Centre |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 16,1 (48 x 0,634) | PE / EP | X65 | 3.070 | 1.460 | 2001 | |
SMI / SNAM Rete Gas | Gas | Italy |
1.220 x 18,9 (48 x 0,744) | PE / EP | X65 | 8.865 | 4.970 | 2001 | |
EVI Energieversorgung Hildesheim |
Erdgasspeicher / Gas storage | Germany |
1.420 x 16,0 (56 x 0,630) | PE / bare | X75 | 1.530 | 850 | 2000 | Erweiterung Erdgasspeicher DN 1400 |
SNAM | Gas | Italy |
762 x 11,1 (30 x 0,437) | PE / EP | X60 | 3.085 | 640 | 2000 | |
VNG | Gas | Germany |
914 x 14,2 (36 x 0,559) | PE / EP | X70 | 680 | 216 | 2000 | VD Bobbau |
VNG | Gas | Germany |
813 x 12,6 (32 x 0,496) | PE / EP | X70 | 930 | 235 | 2000 | VD Bobbau |
VNG | Gas | Germany |
762 x 12,5 (30 x 0,492) | PE / EP | X70 | 300 | 70 | 2000 | VD Bobbau |
VNG | Gas | Germany |
610 x 11,0 (24 x 0,433) | PE / EP | X70 | 152 | 25 | 2000 | VD Bobbau |
VNG | Gas | Germany |
610 x 10,0 (24 x 0,394) | PE / EP | X70 | 404 | 60 | 2000 | VD Bobbau |
VNG | Gas | Germany |
914 x 14,2 (36 x 0,559) | PE / EP | X70 | 564 | 179 | 2000 | FGL 105 |
VNG | Gas | Germany |
813 x 12,5 (32 x 0,492) | PE / EP | X70 | 712 | 177 | 2000 | FGL 105 |
Westfälische Ferngas AG | Gas | Germany |
610 x 8,9 (24 x 0,350) | PE | X70 | 11.610 | 1.550 | 2000 | Lengerich - Ibbenbüren |
Westfälische Ferngas AG | Gas | Germany |
610 x 10,3 (24 x 0,406) | PE | X70 | 400 | 60 | 2000 | Lengerich - Ibbenbüren |
EVG | Gas | Germany |
610 x 9,5 (24 x 0,374) | PE | X70 | 1.426 | 202 | 2000 | Erfurt |
EVN | Gas | Austria |
610 x 10,0 (24 x 0,394) | PE / EP | X60 | 2.360 | 350 | 2000 | Süd 3 - Donaudüker |
EVN | Gas | Austria |
610 x 11,0 (24 x 0,433) | PE / EP | X60 | 830 | 135 | 2000 | Süd 3 - Donaudüker |
Distrigaz | Gas | Belgium |
914 x 12,2 (36 x 0,480) | PE / EP | X70 | 5.560 | 1.580 | 2000 | Zomergen - Nevele |
Distrigaz | Gas | Belgium |
914 x 15,2 (36 x 0,598) | PE / EP | X70 | 415 | 145 | 2000 | Zomergen - Nevele |
Gasunie | Gas | The Netherlands |
610 x 11,1 (24 x 0,437) | bare | X60 | 1.120 | 185 | 2000 | Born - Susterem |
Gasunie | Gas | The Netherlands |
610 x 9,3 (24 x 0,366) | bare | X60 | 450 | 65 | 2000 | Born - Susterem |
NIGC | Gas | Iran |
914 x 10,3 (36 x 0,406) | PE | X65 | 40.000 | 9.182 | 2000 | |
NIGC | Gas | Iran |
914 x 12,7 (36 x 0,500) | PE | X65 | 4.000 | 1.129 | 2000 | |
NIGC | Gas | Iran |
914 x 15,9 (36 x 0,626) | PE | X65 | 2.500 | 880 | 2000 | |
NIGC | Gas | Iran |
914 x 19,05 (36 x 0,750) | PE | X 65 | 7.500 | 3.161 | 2000 | |
Gasunie | Gas | The Netherlands |
762 x 12,0 (30 x 0,472) | bare | X70 | 2.735 | 607 | 2000 | Carnissenlanden - Barendrecht |
Gasunie | Gas | The Netherlands |
914 x 14,3 (36 x 0,563) | bare | X70 | 2.428 | 770 | 2000 | Carnissenlanden - Barendrecht |